8400-M022-O1 Rev K Model 190 Indicator
Hold Function
With the Hold function enabled during setup of the indicator, the function must be activated
before it can be used. Refer to the section Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Hold function.
NOTE: This function is not available when Legal-For-trade (LFt=yes) has been
selected in setup. Also, only one of the functions Hold, Count, Peak Hold,
Checkweigher, or Live Weight can be active at a time.
Activate Hold Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show Hold X, the prompt, and status of the Hold function.
4. If the setting displayed is acceptable, press the TARE key to save it. Otherwise, use
the Fn/ key to toggle to a new setting and press the TARE key to save it.
1
0
= Hold Function Not Active
5. Repeatedly press the TARE key to step through the remaining function prompts until
the indicator returns to the weight display.
Hold Function Operation
1. With the Hold function enabled and activated, momentarily press the Fn/ key and the
display will lock at its current weight reading.
2. Press the PRINT key to print the held reading.
3. Press the NET/GROSS, ZERO, TARE , or UNITS/ key to release the hold and
return to the weight display.