8400-M022-O1 Rev K Model 190 Indicator
67
Live Weight Function
With the Live Weight function enabled during setup of the indicator, the function must be
activated before it can be used. Refer to the section, Function Setup, the FUnC (FUnC?)
parameter to enable the Fn/ key Hold function.
NOTE: This function is not available when Legal-For-trade (LFt=yes) has been
selected in setup. Also, only one of the functions Hold, Count, Peak Hold,
Checkweigher, or Live Weight can be active at a time.
Activate Live Weight Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show ACT X, the prompt, and status of the Live Weight
function.
4. If the setting displayed is acceptable, press the TARE key to save it. Otherwise, use
the Fn/ key to toggle to a new setting and press the TARE key to save it.
1
= Live Weight Function Active
0
= Live Weight Function Not Active
5. Repeatedly press the TARE key to step through the remaining function prompts until
the indicator returns to the weight display.
Live Weight Function Operation
With the Live Weight function enabled and activated, make sure the scale platform is
empty, and then simultaneously press the NET/GROSS and the UNITS/ key.
The Hold annunciator will flash.
Load the scale platform.
When a stable value has been reached, the Hold annunciator will be on steadily and
the display will lock.
Press the NET/GROSS key to return to the weight display.