5.11Programming
SETTABLE PARAMETERS:
Drink
comp.
Element
Min.
value
Max.
value
Unit of measure Various /Remarks
ESPRESSO
Origin Grinder 1
Grinder 2
Decaf
Grinder 1 & 2
Delayed start time 0 300 Tenths of a second
Grinding time 0 150 Tenths of a second
Water dose pulses 0 500 No.
Empty coffee chamber 249 251 No.
Water adding pulses 0 400 No.
Pre-infusion time setting 0 50 Tenths of a second
Pre-infusion pause setting 0 150 Tenths of a second
Coffee expansion chamber 0 30 No.
FRESH BREW
Origin Grinder 1
Grinder 2
Grinder 3
Instant product motor 1
Instant product motor 2
Grinder 1 & 2
Delayed start time 0 300 Tenths of a second
Grinding time 0 150 Tenths of a second
Water time 1 0 200 Tenths of a second
Infusion pause setting 0 150 Tenths of a second
Air pump time 0 150 Tenths of a second
Air pump motor PWM1 1700 1800 No. Recommended
value 1800
Water time 2 0 200 Tenths of a second
Water time 3 0 10 Tenths of a second