5.12
Programming
Drink
comp.
Element
Min.
value
Max.
value
Unit of measure Various /Remarks
INSTANT PRODUCT
Origin Instant product motor 1
Instant product motor 2
Instant product motor 3
Delayed start time 0 300 Tenths of a second
Water dispensing delayed start 0 350 Tenths of a second
Mixer motor time ON 0 370 Tenths of a second
Mixer motor delayed start 0 350 Tenths of a second
Instant product motor time ON 0 350 Tenths of a second
Instant product motor delayed start 5 350 Tenths of a second
Mixer speed setting 0 2 Tenths of a second
Instant product dispensing steps 0 2 No. 0 max speed
1 medium speed
2 min. speed
Instant product dispensing steps 0 2 No. GLVSHQVLQJZLWKRXW
interruption
1 a pause during dis-
pensing
WZRSDXVHVGXULQJ
dispensing
MILK
Milk delayed start time 0 300 Tenths of a second
Steam dispensing time 0 200 Tenths of a second
Milk frother air delayed start 10 160 Tenths of a second
Milk frother air time 0 200 Tenths of a second
Steam delayed start 15 25 Tenths of a second
Active pump time 0 300 Tenths of a second
Active pump speed 20 60 Percentage Value that can be set
for 1% step according
to the max. speed of
WKH SXPS ZLWK OLPLWV
from 20% to 60%.
HOT WATER
Delayed start time 0 300 Tenths of a second
Water dispensing delayed start 0 350 Tenths of a second
NOTE
The elements that can be set for the MILK are available only if the
SDUDPHWHU³6WHDP´LQ³0DFKLQH&RQ¿JXUDWLRQ´LVVHWWR³<HVSXPS´
The machine must be connected to the fridge S DGT.