62-61753-21
7.0A
1A TO 10A
(in 0.5A incre-
ments)
In Start/Stop Operation the alternator charging cur-
rent must drop below this value before the unit is
allowed to shut down.
VOLTAGE FOR START/STOP RE-
START
The engine will restart from a Start/Stop Off cycle or a
Sleep Mode Off cycle when the battery drops to this
value.
A lower selection may result in a longer off cycle
(based on battery voltage) and possibly overall short-
er battery life. A higher selection may result in a
shorter off cycle (based on battery voltage) and pos-
sibly overall longer battery life.
ENGINE TEMPERATURE FOR RE-
START
0°C (32°F)
-12.2°C to 0°C
(10°F to 32°F)
The engine will restart from a Start/Stop Off cycle or a
Sleep Mode Off cycle when the engine coolant tem-
perature drops to this value.
ALTERNATOR CHECK
SHUTDOWN:
YES = When alarm 51 is active the alarm light will
illuminate and the unit will shut down.
NO = When alarm 51 is active the alarm light will
illuminate and the unit will continue to run.
YES = An Engine Oil Level Switch is installed.
NO = An Engine Oil Level Switch is not installed.
ENGINE OIL LEVEL SHUTDOWN
YES = When alarm 2 is active the alarm light will illu-
minate and the unit will shut down.
NO = When alarm 2 is active the alarm light will illu-
minate and the unit will continue to run.
YES = A Coolant Level Sensor is installed.
NO = A Coolant Level Sensor is not installed..
NO DEVICE
DISCREET INPUT
(SWITCH)
0-5 VDC
0.25-4.75 VDC
NOT INSTALLED = There is no Fuel Level Sensor
installed in the fuel tank.
DISCREET INPUT = A Low Fuel Level Switch is in-
stalled in the fuel tank.
0-5 VDC = A Low Fuel Level Sensor with a 0 to
5 VDC signal range is installed in the fuel tank.
0.25-4.75 VDC = A Low Fuel Level Sensor with a
0.25-4.75 VDC signal range is installed in the fuel
tank.
OFF
114 Liters
(30 Gallons)
190 Liters
(50 Gallons)
248 Liters
(75 Gallons)
379 Liters
(100 Gallons)
454 Liters
(120 Gallons)
OFF = No fuel tank installed
30 to 120 GALLON = Size fo fuel tank installed.
(Refer to Fuel Sensor Configuration for additional
information)
DIESEL MAXIMUM GENERATOR
AMPS
26A
10 TO 35
in 0.5A increments
Indicates to the controller the maximum allowable
amperage in Diesel operation.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.