62-61753-21
STANDBY MAXIMUM GENERATOR
AMPS
22A
10 TO 35
in 0.5A increments
Indicates to the controller the maximum allowable
amperage in Standby operation.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
STARTUP MAXIMUM GENERATOR
AMPS
17A
10 TO 35
in 0.5A increments
Indicates to the controller the maximum allowable
amperage during start up.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
DIESEL OFFSET MAXIMUM AMPS
4.0A
0 TO 10
in 0.5A increments
Indicates to the controller the maximum allowable
amperage in low speed operation.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
OFF
5 Seconds
10 Seconds
15 Seconds
20 Seconds
Indicates to the controller the delay for this unit when
starting in standby.
This setting is used when multiple units are on the
same line to stagger the occurrence of high inrush
current in situations such as restart after a power
loss.
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
DISPLAY TOTAL SWITCH ON HR
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
DIESEL RESET VALUE
(Refer to Section 8.2 for oil/filter
change intervals.)
0
50 TO 30,000
hours in 50 hour
increments
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
cate to the controller when the next service interval
alarm will be triggered. If the value entered is "0" the
alarm feature is turned off.
0
50 TO 30,000
hours in 50 hour
increments
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
cate to the controller when the next service interval
alarm will be triggered. If the value entered is "0" the
alarm feature is turned off.
OFF
50 TO 30,000
hours in 50 hour
increments
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
cate to the controller when the next service interval
alarm will be triggered. If the value entered is "0" the
alarm feature is turned off.