MessageCenter MESSAGES
Message
Description
UNIT SHUTDOWN - RMS1(2)
The unit has shut down because switch is open. May be connected to
a door or a remote control switch.
UNKNOWN CARD - REMOVE CARD
A defective PC Card has been inserted into the PC Card slot. The
microprocessor can not recognize any data on the card. The card
may be safely removed from the microprocessor.
WARNING: DIESEL RESTART ON
When electric power is not available while the unit is operating in
Standby Operation, the unit will switch to diesel operation.
WARNING: NO TEMP CONTROL
Both 1RAT and 1SAT alarms are on and unit is running with a set-
point in the frozen range in low speed six cylinder cool.
WRONG UNIT TYPE, REMOVE CARD
A Configuration PC Card has been inserted into the PC Card slot.
The unit model family type on the PC card is not in the same unit
family type as the microprocessor. The card may be safely removed
from the microprocessor.