62-61753-21
6-5
MessageCenter MESSAGES
Message
Description
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides normal
unit Start-Stop or Continuous Run operation. Refer to Section 4.6.3.
READY TO INSTALL SOFTWARE
The microprocessor has been forced into Program Install Mode. If
this message does not clear after loading the current version of soft-
ware, check for a shorted circuit between 5MP5 and 5MP6.
RECOVER / LEAK CHK / EVAC MODE
This message will be displayed when the unit is in Service Mode and
the system is ready for recovery and leak testing.
REMOVE CARD - BATTERY TOO LOW
If a PC card is inserted when battery is below 7.0 volts this message
will be displayed until card is removed.
REMOTE SWITCH 1 (2) OPEN
Remote switch is open. May be connected to a trailer compartment
door or a remote control switch.
REMOTE SWITCH 1 (2) OPEN - LOW
SPEED
Shows that the remote switch is open and that the unit is running in
low speed. Switch may be connected to a trailer compartment door or
a remote control switch.
REMOVE JUMPER
The Configuration/Technician Test Mode has been entered. Remove
the jumper wire before continuing.
SAME SW, = TO LOAD, TO CANCEL
A Program PC Card has been inserted into the PC Card slot and the
program on the PC Card is the same as the program currently in the
microprocessor. Press the = key to reload the same program or press
the UP ARROW key to cancel and remove card.
SERVICE MODE
Selection in Configuration and Technician Test Modes which is used
when servicing the refrigeration system. Refer to Section 5.1.3.
SETPOINT CHANGED
The new set point has been entered (saved into microprocessor
memory), the new set point will be used.
SETPOINT NOT CHANGED
The new set point has NOT been entered (NOT saved into micropro-
cessor memory), the old set point will be used.
SETTING SMV: XXX %
The START/RUN-OFF switch has been placed in the
START/RUN position and the CSMV is opening.
SLEEP MODE, OFF / ON TO WAKE
The unit is cycled off in Sleep Mode. Place the
START/RUN-OFF switch in the OFF position, then back to the
START/RUN position to wake the microprocessor up.
SLEEP WARNING: NO TEMP CONTROL
The unit is running in Sleep Mode to charge the battery and (in en-
gine operation) warm the engine coolant. It is not running to provide
temperature control.
SMV CLOSING: WAIT XXX SECONDS
Power Up and the CSMV is closing. XX indicates the number of sec-
onds remaining until valve is fully closed.
START MODE: AUTO or MANUAL
Indicates whether the unit is in Auto Start or Manual Start mode
START STOP LOCKED
The set point has been locked into the Start-Stop mode. Continuous
Run can not be selected.
START/STOP MODE SELECTED
Start-Stop Mode has been selected.
STATUS OK
The unit is operating correctly.
TEST #1 to #15
Pretrip is currently running this test and is x% complete.
TIME SELECTION NOT CHANGED
A time change was started but not entered (saved) in Configuration
List.
TRIP START ENTERED
The Trip Start marker has been placed in the DataRecorder.
UNIT BATTERY TOO LOW
The unit battery has dropped below 7 volts for more than 10 seconds.
UNIT SHUTDOWN - DOOR OPEN
The unit has shut down because the refrigerated compartment door
is open.
UNIT SHUTDOWN - SEE ALARM LIST
An active shutdown alarm has shut the unit down.