6-MAINTENANCE
Startingupafterstorage
WARNING
Unexpectedmachinemovement!
Beforestartingtheengine,makesureallcontrolsareintheneutralposition.
Failuretocomplycouldresultindeathorseriousinjury.
W0311A
WARNING
Inhalationhazard!Risktooperatorsandbystanders.
Avoidrunningtheengineinconnedareas.Makesurethereisadequateventilationatalltimes.
Failuretocomplycouldresultindeathorseriousinjury.
W0156A
1.Drainthefueltank,thepre-lterandthefuellter,re-
placethelterelementsifnecessary.
2.Fillthefueltankwithsuitablefuel.(Refertopage6-4).
3.Installthebatteriesorreconnectthecabletothenega-
tive(-)terminal.
4.Greasethemachinethoroughly.
5.Checktheconditionofthefandrivebeltandreplaceit
ifnecessary.
6.Checktheconditionoftheairconditioningdrivebelt
andreplaceitifnecessary.
7.Checkthecoolingsystemlevelandaddmorecoolant
ifnecessary.
8.Checkthehydraulicuidlevelandaddmoreuidif
necessary.
9.Checkthetravelreductiongearsandswingreduction
gearoillevelandaddmoreoilifnecessary.
10.Cleanthecylinderrods.
11.Unplugtheairlterinletandtheexhaustpipe.
12.Removethe"Donotoperate"tagandstarttheengine,
followingthestartingupprocedure.
13.Checkalltheindicatorsandlampscarefully.
NOTICE:Checkthemachineandtheengineforleaksorforanypartsthatarebroken,defectiveormissing.