3-CONTROLSANDINSTRUMENTS
Notethatifregenerationisstoppedforalongtime,itshiftstomanualregeneration.
PresstheDPDswitch.
○
ThegreenDPDlampgoesout.
○
Thefollowingmessageisdisplayed.
PushDPDswitchtoactivate
Automaticregenerationstops.
Aftertheworkiscompleted,performcooling.
PresstheDPDswitchagaintorestartautomaticregeneration.
•
ThegreenDPDlamplightsup.
•
Theindicatorlightsup.
•
Thebuzzersoundsfor2seconds.
•
Thefollowingmessageisdisplayed.
AutoDPDRe-gen
Automaticregenerationstarts.
Manualregeneration
XNNFHF-001Z5
Normaloperationisdisabledinmanualregeneration.
Whenmanualregenerationstarts,enginerevolutionsarereducedautomaticallyandtheenginesoundandhydraulic
operationsoundchange.
Thesedonotimplyanyproblems.
Ifoperationcontinueswhentheorangelampblinks,thediffusermaybefaulty.
Movetoasafeplaceasquicklyaspossibleandexecuteregeneration.
Iftheswitchisnotpressedforalongtime,theorangelampchangesfromslowtofastblinking.
Iftheswitchisnotpressedatthistime,theengineproblemwarninglampgoesonandthediffuserneedstobe
repaired.
NOTE:ConsultyourCASECONSTRUCTIONDealerifaredDPDiconisdisplayed.
Manualregenerationnishesearlierimmediatelyafterthemachinerunsthanwhentheengineiscool.
Thewatertemperaturemayriseduringmanualregeneration.
3-41