Large-Scale Deployment Installation
R81.10.X Quantum Spark 1500, 1600, 1800, 1900, 2000 Appliances Centrally Managed Administration Guide|58
n
Internal - Sync: one interface for each Cluster Member
The network addresses (for example, 1.1.1.194) for each interface are not the
actual addresses for your SmartLSM Cluster environment. Those are used for the
template. The actual network addresses are modified in the next configuration step
in the SmartProvisioning application.
Important - The host octet for each member's interface address such as
"59" for Member1 - WAN (for example, 1.1.1.59) must be its real host
address and cannot be modified. Make sure to configure it correctly.
The host octet for the Virtual IP addresses can be modified later.
6. For each Virtual IP interface, double-click the text field to enter the interface name,
Security Zone, network type, IP address, and Net Mask.
7. For the Internal and Sync interfaces, select Network defined by the interface IP and
Net Mask. Set Anti-Spoofing for each interface in the Anti-Spoofing tab. Keep the
default settings in the Member Network tab.
8. For each cluster member, double-click the Topology text field to enter the interface
name, IP address, and Net Mask. For VLANs, make sure the member names use the
actual physical interface names on the machines. Note that these are the same names
that are shown in the appliance's WebUI, but replace the colon character ":" with a period
character "."
For example, if the WebUI shows LAN1:10, enter here LAN1.10
9. Click Save and install policy on the Cluster Profile.
10. Install the applicable Security Policy on the Cluster SmartLSM profile.
11. Click Menu > SmartProvisioning. Continue the configuration in the SmartProvisioning
GUI.
Deploying with SmartProvisioning
You can use SmartProvisioning to manage Quantum Spark appliance gateways with the
SmartLSM profiles defined in SmartConsole. Configure these appliances using the First Time
Configuration Wizard or a USB drive configuration file before you manage them with
SmartProvisioning.
For more information about large-scale deployment using SmartProvisioning, see the
SmartProvisioning Administration Guide
for your Management Server version.

Table of Contents

Other manuals for Check Point QUANTUM SPARK 1570

Related product manuals