GPIB/RS232 Interface (IEEE-488.2)
Example: Input the command SAF:STAR:CORR:SAMP GET
Description: It means to start the GET Cs function in Open Short Check mode.
[:SOURce]:SAFety:STARt:CORRection:SAMPle?
It queries if the GET Cs function is started in Open Short Check mode.
Example: Input the command SAF:STAR:CORR:SAMP ?
The tester returns 1
Description: The returned 1 means the GET Cs function has been started in Open
Short Check mode.
[:SOURce]:SAFety:STATus?
It queries the execution status of present device. The string returned is RUNNING|
STOPPED.
Example: Input the command SAF:STAT?
The tester returns RUNNING.
Description: The returned RUNNING means the host is conduction tests at
present.
[:SOURce]:SAFety:STEP<n>:AC:CHANnel[:CLOSe] <channel_list>
It sets the status of high voltage output channel in selected STEP.
Example: Input the command SAF:STEP1:AC:CHAN (@001,002,201:210)
Description: It means to start the high voltage output channel CH1, CH2 in STEP 1
for Address 0 host, also start the high voltage output channel
CH1~CH10 of Address 2 host.
[:SOURce]:SAFety:STEP<n>:AC:CHANnel[:CLOSe]?
It queries the status of high voltage output channel for selected STEP.
Example: Input the command SAF:STEP1:AC:CHAN?
The tester returns (@001,002,201:210).
Description: The returned result indicates the high voltage output channels CH1
and CH2 of Address 0 host and the channels CH1~CH10 of Address
2 host in STEP 1 are started.
[:SOURce]:SAFety:STEP<n>:AC:CHANnel:DEFault:ON
It sets the selected STEP to use the option of DEF. CHANNELS in TEST CONTROL for
setting high voltage output channel.
Example: Input the command SAF:STEP1:AC:CHAN:DEF:ON
Description: It means to set STEP 1 using the option of DEF. CHANNELS in TEST
CONTROL for setting high voltage output channel.
[:SOURce]:SAFety:STEP<n>:AC:CHANnel:DEFault:STATe?
It queries if the selected STEP is using the option of DEF. CHANNELS in TEST
CONTROL for setting high voltage output channel.
Example: Input the command SAF:STEP1:AC:CHAN:DEF:STAT?
The tester returns 1.
Description: The returned 1 means STEP 1 is using the option of DEF.
CHANNELS in TEST CONTROL for setting high voltage output