Material Contents Declaration
The recycling label shown on the product indicates the Hazardous Substances contained in
the product as the table listed below.
: See <Table 1>.
: See <Table 2>.
<Table 1>
Part Name
Hazardous Substances
Lead
Mercury
Cadmium
Hexavalent
Chromium
Polybrominated
Biphenyls/
Polybromodiphenyl
Ethers
Selected Phthalates
Group
Pb
Hg
Cd
Cr
6+
PBB/PBDE
DEHP/BBP/DBP/DIBP
PCBA
O O O O O O
CHASSIS
O O O O O O
ACCESSORY
O O O O O O
PACKAGE
O O O O O O
“O” indicates that the level of the specified chemical substance is less than the threshold level
specified in the standards of SJ/T
-11363-2006 and EU Directive 2011/65/EU.
” indicates that the level of the specified chemical substance exceeds the threshold level
specified in the standards of SJ/T
-11363-2006 and EU Directive 2011/65/EU.
Remarks:
The CE marking on product is a declaration of product compliance with EU
Directive 2011/65/EU.
Disposal
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging your health and
well-being. When replacing old appliances with new one, the retailer is legally obligated to
take back your old appliances for disposal at least for free of charge.

Table of Contents

Other manuals for Chroma 19032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 19032 and is the answer not in the manual?

Chroma 19032 Specifications

General IconGeneral
CategoryMeasuring Instruments
DisplayLCD
Model19032
Test FunctionsAC Withstand Voltage, DC Withstand Voltage, Insulation Resistance, Ground Bond, Leakage Current
AC Test Voltage0.05 kV AC ~ 5.00 kV AC
DC Test Voltage0.05 kV DC ~ 6.00 kV DC
Ground Bond Resistance1 mΩ ~ 650 mΩ
Leakage Current2 μA AC ~ 20 mA AC, 0.2 μA DC ~ 2 mA DC
AC Withstand Voltage0.05 kV AC ~ 5.00 kV AC
DC Withstand Voltage0.05 kV DC ~ 6.00 kV DC
Safety StandardIEC
Power Supply100 V AC ~ 240 V AC, 50 Hz / 60 Hz
Operating Temperature0 °C ~ 40 °C
Ground Bond Current1A to 40A
Ground Bond1A to 40A