Remote Operation
4-45
DIGitizing:INITiate
Type: Channel-Specific
Description: Start the digitizing function to wait trigger signal.
Setting Syntax : DIGitizing:INITiate
Setting Parameters:None
Setting Example: DIG:INIT Initial digitizing function.
Query Syntax: None
Return Parameters:None
Query Example: None
DIGitizing:SAMPling:POINt
Type: Channel-Specific
Description: Set the sampling points for digitizing function.
Setting Syntax: DIGitizing:SAMPling:POINt<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 15,000, Resolution = 1, Unit = None
Setting Example: DIG:SAMP:POIN 500 Set sampling points = 500
DIG:SAMP:POIN MAX Set sampling points = maximum
value.
DIG:SAMP:POIN MIN Set sampling points = minimum
value.
Query Syntax: DIGitizing:SAMPling:POINt?[<space><MAX | MIN>]
Return Parameters:<NR1>, [Unit = None]
Query Example: DIG:SAMP:POIN?
DIG:SAMP:POIN? MAX
DIG:SAMP:POIN? MIN
DIGitizing:SAMPling:TIME
Type: Channel-Specific
Description: Set the sampling time for digitizing function.
Setting Syntax: DIGitizing:SAMPling:TIME<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 2μs ~ 40ms, Resolution = 2μs, Unit = Second
Setting Example: DIG:SAMP:TIME 0.02 Set sampling time = 20ms
DIG:SAMP:TIME 20ms Set sampling time = 20ms
DIG:SAMP:TIME MAX Set sampling time = maximum
value.
DIG:SAMP:TIME MIN Set sampling time = minimum
value.
Query Syntax: DIGitizing:SAMPling:TIME?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example: DIG:SAMP:TIME?
DIG:SAMP:TIME? MAX
DIG:SAMP:TIME? MIN
DIGitizing:TRIGger[:STATe]
Type: Channel-Specific
Description: Set the software trigger for digitizing function.
Setting Syntax: DIGitizing:TRIGger[:STATe]<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1) [Unit = None]
Setting Example: DIG:TRIG ON Set trigger state to ON.
DIG:TRIG 0 Set trigger state to OFF.
Query Syntax: DIGitizing:TRIGger[:STATe]?
Return Parameters:<CRD>, IDLE, PRE_TRIG, WAIT_TRIG, POST_TRIG
Query Example: DIG:TRIG?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200A Series and is the answer not in the manual?

Chroma 63200A Series Specifications

General IconGeneral
BrandChroma
Model63200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals