High Power Electronic Load 63200A Series Operation & Programming Manual
Return Parameters:<NR2>, [Unit = Volt]
Query Example: SPEC:VOLT:H?
SPEC:VOLT:H? MAX
SPEC:VOLT:H? MIN
SPECification:VOLTage:L
Type: Channel-Specific
Description: Set the low-level voltage specification. The -1 mean don’t care.
Setting Syntax: SPECification:VOLTage:L<space><NRf+>[suffix]
Parameters: Refer to respective specification for valid value range.
Setting Example: SPEC:VOLT:L 20
SPEC:VOLT:L 20mV
Query Syntax: SPECification:VOLTage:L?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: SPEC:VOLT:L?
SPEC:VOLT:L? MAX
SPEC:VOLT:L? MIN
FETCH Subsystem 4.3.2.11
FETCh:AH?
Type: Channel-Specific
Description: Returns the ampere-hour measured in timing mode.
Query Syntax: FETCh:AH?
Return Parameters:<NR2>, [Unit = Ampere-hour]
Query Example: FETC:AH?
Return Example: 3.15
FETCh:CURRent?
Type: Channel-Specific
Description: Returns the current measured at electronic load input.
Query Syntax: FETCh:CURRent?
Return Parameters:<NR2>, [Unit = Ampere]
Query Example: FETC:CURR?
Return Example: 3.15
FETCh:CURRent:PEAK+?
Type: Channel-Specific
Description: Returns the peak+ current measured at electronic load input in CZ
mode.
Query Syntax: FETCh:CURRent:PEAK+?
Return Parameters:<NR2>, [Unit = Ampere]
Query Example: FETC:CURR:PEAK+?
Return Example: 3.15
FETCh:FREQuency?
Type: Channel-Specific
Description: Returns the frequency measured in frequency sweep mode or sine
wave dynamic mode.
Query Syntax: FETCh:FREQuency?
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: FETC:FREQ?