Page #107 background imageLoading...
Page #107 background image
High Power Electronic Load 63200A Series Operation & Programming Manual
4-44
[ADVance:]EXTernal:WAVeform:CC:VRNG
Type: Channel-Specific
Description: Set the voltage measurement range in external waveform when the
mode is set to CC mode.
Setting Syntax: [ADVance:]EXTernal:WAVeform:CC:VRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CC:VRNG HIGH Set voltage range to High.
EXT:WAV:CC:VRNG M Set voltage range to Middle.
EXT:WAV:CC:VRNG 0 Set voltage range to Low.
Query Syntax: EXTernal:WAVeform:CC:VRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2) [Unit = None]
Query Example: EXT:WAV:CC:VRNG?
[ADVance:]EXTernal:WAVeform:CR:IRNG
Type: Channel-Specific
Description: Set the current measurement range in external waveform when the
mode is set to CR mode.
Setting Syntax: [ADVance:]EXTernal:WAVeform:CR:IRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CR:IRNG HIGH Set current range to High.
EXT:WAV:CR:IRNG M Set current range to Middle.
EXT:WAV:CR:IRNG 0 Set current range to Low.
Query Syntax: EXTernal:WAVeform:CR:IRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2) [Unit = None]
Query Example: EXT:WAV:CR:IRNG?
[ADVance:]External:WAVeform:CV:IRNG
Type: Channel-Specific
Description: Set the current measurement range in external waveform when the
mode is set to CV mode.
Setting Syntax: [ADVance:]EXTernal:WAVeform:CV:IRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: EXT:WAV:CV:IRNG HIGH Set current range to High.
EXT:WAV:CV:IRNG M Set current range to Middle.
EXT:WAV:CV:IRNG 0 Set current range to Low.
Query Syntax: EXTernal:WAVeform:CV:IRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2) [Unit = None]
Query Example: EXT:WAV:CV:IRNG?
DIGITIZING Subsystem 4.3.2.9
DIGitizing:ABORt
Type: Channel-Specific
Description: Abort the digitizing function.
Setting Syntax : DIGitizing:ABORt
Setting Parameters:None
Setting Example: DIG:ABOR Abort digitizing function.
Query Syntax: None
Return Parameters:None
Query Example: None

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200A Series and is the answer not in the manual?

Chroma 63200A Series Specifications

General IconGeneral
BrandChroma
Model63200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals