Remote Operation
CURR:DYN:FALL? MIN
CURRent:DYNamic:VRNG
Type: Channel-Specific
Description: Set the voltage measurement range in CCD mode.
Setting Syntax: CURRent:DYNamic:VRNG<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example: CURR:DYN:VRNG HIGH Set voltage range to High.
CURR:DYN:VRNG M Set voltage range to Middle.
CURR:DYN:VRNG 0 Set voltage range to Low.
Query Syntax: CURRent: DYNamic: VRNG?
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2) [Unit = None]
Query Example: CURR:DYN:VRNG?
RESISTANCE Subsystem 4.3.2.5
RESistance:STATic:L1
Type: Channel-Specific
Description: Set static resistance level for constant resistance mode.
Setting Syntax: RESistance:STATic:L1<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: RES:STAT:L1 20 Set constant resistance = 20Ω
for Load L1.
RES:STAT:L1 10 OHM Set constant resistance = 10Ω
for Load L1.
RES:STAT:L1 MAX Set constant resistance = maximum
value for Load L1.
RES:STAT:L1 MIN Set constant resistance = minimum
value for Load L1.
Query Syntax: RESistance:STATic:L1?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = OHM]
Query Example: RES:STAT:L1?
RES:STAT:L1? MAX
RES:STAT:L1? MIN
RESistance:STATic:L2
Type: Channel-Specific
Description: Set static resistance level for constant resistance mode.
Setting Syntax: RESistance:STATic:L2<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: RES:STAT:L2 20 Set constant resistance = 20Ω
for Load L2.
RES:STAT:L2 10 OHM Set constant resistance = 10Ω
for Load L2.
RES:STAT:L2 MAX Set constant resistance = maximum
value for Load L2.
RES:STAT:L2 MIN Set constant resistance = minimum
value for Load L2.
Query Syntax: RESistance:STATic:L2?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = OHM]
Query Example: RES:STAT:L2?
RES:STAT:L2? MAX