Remote Operation
4-43
Setting Example: AUTO:RSET 20 Set the RSET = 20Ω.
AUTO:RSET 10 OHM Set the RSET = 10Ω.
AUTO:RSET MAX Set the RSET = maximum value.
AUTO:RSET MIN Set the RSET = minimum value.
Query Syntax: [ADVance:]AUTO:RSET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = OHM]
Query Example: AUTO:RSET?
AUTO:RSET? MAX
AUTO:RSET? MIN
[ADVance:]AUTO:ISET
Type: Channel-Specific
Description: Set the static load current in AUTO mode.
Setting Syntax: [ADVance:]AUTO:ISET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: AUTO:ISET 20 Set the ISET = 20A.
AUTO:ISET 10A Set the ISET = 10A.
AUTO:ISET MAX Set the ISET = maximum value.
AUTO:ISET MIN Set the ISET = minimum value.
Query Syntax: [ADVance:]AUTO:ISET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere]
Query Example: AUTO:ISET?
AUTO:ISET? MAX
AUTO:ISET? MIN
[ADVance:]AUTO:PSET
Type: Channel-Specific
Description: Set the static load power in AUTO mode.
Setting Syntax: [ADVance:]AUTO:PSET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: AUTO:PSET 20 Set the PSET = 20W.
AUTO:PSET 10W Set the PSET = 10W.
AUTO:PSET MAX Set the PSET = maximum value.
AUTO:PSET MIN Set the PSET = minimum value.
Query Syntax: [ADVance:]AUTO:PSET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Watt]
Query Example: AUTO:PSET?
AUTO:PSET? MAX
AUTO:PSET? MIN
[ADVance:]EXTernal:WAVeform:MODE
Type: Channel-Specific
Description: Set run mode in external waveform mode.
Setting Syntax: [ADVance:]External:WAVeform:MODE<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, CC(0), CR(1), CV(2)
Setting Example: BATT:MODE CC Set run mode = CC
BATT:MODE 2 Set run mode = CV
Query Syntax: [ADVance:]EXTernal:WAVeform:MODE?
Return Parameters:<CRD>, CC(0), CR(1), CV(2) [Unit = None]
Query Example: EXT:WAV:MODE?