High Power Electronic Load 63200A Series Operation & Programming Manual
4-42
CRCC:ISET? MAX
CRCC:ISET? MIN
[ADVance:]CVCR:VSET
Type: Channel-Specific
Description: Set the static load voltage in CV+CR mode.
Setting Syntax: [ADVance:]CVCR:VSET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CVCR:VSET 8 Set VSET as 8V.
CVCR:VSET 24V Set VSET as 24V.
CVCR:VSET MAX Set VSET as the maximum value.
CVCR:VSET MIN Set VSET as the minimum value.
Query Syntax: [ADVance:]CVCR:VSET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: CVCR:VSET?
CVCR:VSET? MAX
CVCR:VSET? MIN
[ADVance:]CVCR:RSET
Type: Channel-Specific
Description: Set static resistance level in CV+CR mode.
Setting Syntax: [ADVance:]CVCR:RSET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CVCR:RSET 20 Set the RSET = 20Ω.
CVCR:RSET 10 OHM Set the RSET = 10Ω.
CVCR:RSET MAX Set the RSET = maximum value.
CVCR:RSET MIN Set the RSET = minimum value.
Query Syntax: [ADVance:]CVCR:RSET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = OHM]
Query Example: CVCR:RSET?
CVCR:RSET? MAX
CVCR:RSET? MIN
[ADVance:]AUTO:VSET
Type: Channel-Specific
Description: Set the static load voltage in AUTO mode.
Setting Syntax: [ADVance:]AUTO:VSET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: AUTO:VSET 8 Set VSET as 8V.
AUTO:VSET 24V Set VSET as 24V.
AUTO:VSET MAX Set VSET as the maximum value.
AUTO:VSET MIN Set VSET as the minimum value.
Query Syntax: [ADVance:]AUTO:VSET?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: AUTO:VSET?
AUTO:VSET? MAX
AUTO:VSET? MIN
[ADVance:]AUTO:RSET
Type: Channel-Specific
Description: Set static resistance level in AUTO mode.
Setting Syntax: [ADVance:]AUTO:RSET<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200A Series and is the answer not in the manual?

Chroma 63200A Series Specifications

General IconGeneral
BrandChroma
Model63200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals