Remote Operation
4-11
CONFigure:VOLTage:LATCh
Type: Channel-Specific
Description: Set the action type of Von.
Setting Syntax: CONFigure:VOLTage:LATCh<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, OFF(0),ON(1)
Setting Example: CONF:VOLT:LATC OFF Set Von latch function to OFF.
CONF:VOLT:LATC 1 Set Von latch function to ON.
Query Syntax: CONFigure:VOLTage:LATCh?
Return Parameters:<CRD>, OFF(0), ON(1) [Unit = None]
Query Example: CONF:VOLT:LATC?
CONFigure:VOLTage:LATCh:RESet
Type: Channel-Specific
Description: Resets the Von signal.
Setting Syntax: CONFigure:VOLTage:LATCh:RESet
Setting Parameters:None.
Setting Example: CONF:VOLT:LATC:RES Resets the Von Signal.
CONFigure:VOLTage:SIGN
Type: Channel-Specific
Description: Set the sign of voltage measurement to Plus/Minus.
Setting Syntax: CONFigure:VOLTage:SIGN<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, PLUS(0), MINUS(1)
Setting Example: CONF:VOLT:SIGN PLUS Set sign of voltage to Plus.
CONF:VOLT:SIGN 1 Set sign of voltage to Minus.
Query Syntax: CONFigure:VOLTage:SIGN?
Return Parameters:<CRD>, PLUS(0), MINUS(1) [Unit = None]
Query Example: CONF:VOLT:SIGN?
CONFigure:WINDow
Type: Channel-Specific
Description: Set the time of measure over which the window calculation is to be
performed.
Setting Syntax: CONFigure:WINDow<space><NRf+>
Setting Parameters:<NRf+>, 0.02s ~ 61.00s, Resolution = 20ms, Unit = Second
Setting Example: CONF:WIND 0.5 Set times of window = 0.5s
CONF:WIND MAX Set times of window = maximum value.
CONF:WIND MIN Set times of window = minimum value.
Query Syntax: CONFigure:WINDow?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example: CONF:WIND?
CONF:WIND? MAX
CONF:WIND? MIN
CONFigure:SYNChronous:MODE
Type: Channel-Specific
Description: Set the synchronization mode.
Setting Syntax: CONFigure:SYNChronous:MODE<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: CONF:SYNC:MODE MASTER Set sync. mode to MASTER.
CONF:SYNC:MODE 0 Set sync. mode to NONE.
Query Syntax: CONFigure:SYNChronous:MODE?
Return Parameters:<CRD>, NONE(0), MASTER(1), SLAVE(2) [Unit = None]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63200A Series and is the answer not in the manual?

Chroma 63200A Series Specifications

General IconGeneral
BrandChroma
Model63200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals