EasyManua.ls Logo

Chroma 63600 Series - Page 185

Default Icon
258 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
5-53
Type: Channel-Specific
Description: Set the end of frequency for constant current frequency sweep
mode.
Setting Syntax: CURRent:SWEep:FEND<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example: CURR:SWE:FEND 1000 Set frequency = 1kHz
CURR:SWE:FEND 1kHz Set frequency = 1kHz
CURR:SWE:FEND MAX Set frequency = maximum value.
CURR:SWE:FEND MIN Set frequency = minimum value.
Query Syntax: CURRent:SWEep:FEND?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: CURR:SWE:FEND?
CURR:SWE:FEND? MAX
CURR:SWE:FEND? MIN
CURRent:SWEep:FSTArt
Type: Channel-Specific
Description: Set the start of frequency for constant current frequency sweep
mode.
Setting Syntax: CURRent:SWEep:FSTArt<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example: CURR:SWE:FSTA 1000 Set frequency = 1kHz
CURR:SWE:FSTA 1kHz Set frequency = 1kHz
CURR:SWE:FSTA MAX Set frequency = maximum value.
CURR:SWE:FSTA MIN Set frequency = minimum value.
Query Syntax: CURRent:SWEep:FSTA?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: CURR:SWE:FSTA?
CURR:SWE:FSTA? MAX
CURR:SWE:FSTA? MIN
CURRent:SWEep:FSTEp
Type: Channel-Specific
Description: Set the step of frequency for constant current frequency sweep
mode.
Setting Syntax: CURRent:SWEep:FSTEp<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example: CURR:SWE:FSTE 1000 Set frequency = 1kHz
CURR:SWE:FSTE 1kHz Set frequency = 1kHz
CURR:SWE:FSTE MAX Set frequency = maximum value.
CURR:SWE:FSTE MIN Set frequency = minimum value.
Query Syntax: CURRent:SWEep:FSTE?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: CURR:SWE:FSTE?
CURR:SWE:FSTE? MAX
CURR:SWE:FSTE? MIN
CURRent:SWEep:IMAXimum
Type: Channel-Specific
Description: Set the maximum current for constant current frequency sweep
mode.
Setting Syntax: CURRent:SWEep:IMAXimum<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CURR:SWE:IMAX 20 Set max current = 20A.