Auto Power Off Mode Press the scan trigger to start with scanning.
The scanning won't stop until the preset timeout expires, and, the
preset timeout period re-counts after each successful decoding.
Read Redundancy None
None No redundancy means one successful decoding will make the reading valid
and induce the "READER Event".
One time, Two times,
or Three times
The higher the reading security is (that is, the more redundancy the user
selects), the slower the reading speed gets.
If "Three Times" is selected, it will take a total of four consecutive
successful decodings of the same barcode to make the reading valid.
SYMBOLOGY SETTINGS TABLE
CCD/Laser Description Default
Codabar Enable
Transmit Start/Stop
Characters
Decide whether to include the start/stop characters in the
data being transmitted.
If "Transmit Start/Stop Characters" is desired, select one
set:
abcd / abcd
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
No
Code 128 Enable
GS1-128 Enable
Transmit Code ID (for
GS1-128)
Decide whether to include Code ID (“]C1”) will be included
in the data being transmitted.
No
Field Separator
Replacement
Decide whether to replace the field separator. If the
barcode contains Field Separator “0x1D”, it will be
changed to the desired Field Separator. For example, type
the desired character “;” (semicolon) as the new field
separator. Then if the barcode contains Field Separator
“0x1D”, it will be changed to “;”.
No
Industrial 25 (= Discrete 25) Enable
Start/Stop Selection
T
his decides the readability of all 2 of 5 symbology
variants. For example, flight tickets actually use an
Industrial 2 of 5 barcode but with Interleaved 2 of 5
start/stop pattern. In order to read this barcode, the
start/stop pattern selection parameter of Industrial 2 of 5
should set to "Interleaved 25".
Industrial 25
Verify Check Digit Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Yes

Table of Contents

Other manuals for CipherLab 8001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab 8001 and is the answer not in the manual?

CipherLab 8001 Specifications

General IconGeneral
BrandCipherLab
Model8001
CategoryDocking Station
LanguageEnglish