CHAPTER 4
Chassis Installation
This chapter describes how to install the ASR 5500 chassis and its components.
The ASR 5500 is suitable for installation in Network Telecommunication Facilities designed for unattended
equipment operation.
Important
This chapter includes the following sections:
Mounting Options, page 31
Weight Considerations, page 32
Unpacking the Chassis, page 32
Reducing the Weight of the Chassis Prior to Installation, page 35
Installing the Chassis, page 40
Grounding the Chassis, page 43
Re-Installing Chassis Components, page 45
Cable Management System, page 47
Mounting Options
There are two options for mounting the chassis in a standard 19-inch equipment rack or telecommunications
cabinet:
Flush mount: In this configuration, the flanges of the mounting brackets are flush with the front of the
chassis. This is the default configuration as shipped. This method is typically used to mount the chassis
in a 4-post rack or equipment cabinet. Refer to
Mid-mount: In this configuration, the flanges of the mounting brackets are recessed from the front of
the chassis. To do this, the mounting brackets must be removed and reinstalled toward the middle of the
chassis. This method is typically used to mount the chassis in a two-post rack. Refer to
ASR 5500 Installation Guide