Site Selection Guidelines
The router require specific environmental operating conditions. Temperature, humidity, altitude, and vibration
can affect the performance and reliability of the router. The following sections provide specific information
to help you plan for the proper operating environment.
The routers are designed to meet the industry EMC, safety, and environmental standards described in the
Regulatory Compliance and Safety Information for the Cisco ASR 920 Series Router document.
Environmental Requirements
Environmental monitoring of the Cisco ASR 920-24SZ-IM, ASR-920-24SZ-M, ASR-920-24TZ-M Router
protects the system and components from damage caused by excessive voltage and temperature conditions.
To ensure normal operation and avoid unnecessary maintenance, plan and prepare your site configuration
before installation. After installation, make sure that the site maintains the environmental characteristics
described in Cisco ASR-920-12SZ-IM Router Specifications table.
For an outside plant installation (cell site cabinet, hut etc.), it is required that the router be protected against
airborne contaminants, dust, moisture, insects, pests, corrosive gases, polluted air or other reactive elements
present in the outside air. To achieve this level of protection, we recommend that the unit be installed in a
fully sealed enclosure or cabinet. Examples of such cabinets include IP65 cabinets with heat exchanger
complying with Telecordia GR487. Temperature must be maintained within 40º C to 70º C.
The equipment shall be placed inside a space protected from direct outside weather and environmental stresses
by an enclosure, and where the operating climate, as defined by Class 2 of GR-3108-CORE, is between
-40°C (-40°F) and 70°C (158°F)
5 and 90% RH
Physical Characteristics
Be familiar with the physical characteristics of the router to assist you in placing the system in the proper
location. For more information, see Cisco ASR-920-12SZ-IM Router Specifications table.
Air Flow Guidelines
Cool air is circulated through the router by fans located along the back side of the router.
The internal fans maintain acceptable operating temperatures for the internal components by drawing in cool
air through the vents, and circulating the air through the chassis.
Cisco ASR-920-12SZ-IM Aggregation Services Router Hardware Installation Guide
24
Preparing for Installation
Site Selection Guidelines

Table of Contents

Other manuals for Cisco ASR-920-12SZ-IM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR-920-12SZ-IM and is the answer not in the manual?

Cisco ASR-920-12SZ-IM Specifications

General IconGeneral
DSL WANNo
Ethernet WANYes
Networking standardsIEEE 802.3x
Ethernet LAN data rates10, 100, 1000, 10000 Mbit/s
USB ports quantity2
Ethernet LAN (RJ-45) ports8
Product colorGray
Rack capacity1U
Antenna typeNot supported
AC input voltage100 - 240 V
Power source typeAC, DC, PoE
AC input frequency50 - 60 Hz
Power consumption (typical)130 W
Non-operating altitude0 - 4570 m
Operating temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)5 - 95 %
SafetyUL 60950-1, 2005, CAN/CSA C22.2 No. 60950-1: 2005, IEC 60950-1, 2005, EN 60950-1, 2005, AS/NZS 60950.1:2005
Electromagnetic compatibilityFCC CFR47 Part 15 Class A
Mean time between failures (MTBF)407230 h
Firewall-
Security algorithmsIPSec
Weight and Dimensions IconWeight and Dimensions
Depth286.54 mm
Width444.5 mm
Height44 mm
Weight4830 g