Each database entry (binding) has an IP address, an associated MAC address, the lease time (in hexadecimal
format), the interface to which the binding applies, and the VLAN to which the interface belongs. The database
agent stores the bindings in a file at a configured location. At the end of each entry is a checksum that accounts
for all the bytes from the start of the file through all the bytes associated with the entry. Each entry is 72 bytes,
followed by a space and then the checksum value.
To keep the bindings when the switch reloads, you must use the DHCP snooping database agent. If the agent
is disabled, dynamic ARP inspection or IP source guard is enabled, and the DHCP snooping binding database
has dynamic bindings, the switch loses its connectivity. If the agent is disabled and only DHCP snooping is
enabled, the switch does not lose its connectivity, but DHCP snooping might not prevent DHCP spoofing
attacks.
When reloading, the switch reads the binding file to build the DHCP snooping binding database. The switch
updates the file when the database changes.
When a switch learns of new bindings or when it loses bindings, the switch immediately updates the entries
in the database. The switch also updates the entries in the binding file. The frequency at which the file is
updated is based on a configurable delay, and the updates are batched. If the file is not updated in a specified
time (set by the write-delay and abort-timeout values), the update stops.
This is the format of the file with bindings:
<initial-checksum>
TYPE DHCP-SNOOPING
VERSION 1
BEGIN
<entry-1> <checksum-1>
<entry-2> <checksum-1-2>
...
...
<entry-n> <checksum-1-2-..-n>
END
Each entry in the file is tagged with a checksum value that the switch uses to verify the entries when it reads
the file. The initial-checksum entry on the first line distinguishes entries associated with the latest file update
from entries associated with a previous file update.
This is an example of a binding file:
2bb4c2a1
TYPE DHCP-SNOOPING
VERSION 1
BEGIN
192.1.168.1 3 0003.47d8.c91f 2BB6488E Gi1/0/4 21ae5fbb
192.1.168.3 3 0003.44d6.c52f 2BB648EB Gi1/0/4 1bdb223f
192.1.168.2 3 0003.47d9.c8f1 2BB648AB Gi1/0/4 584a38f0
END
When the switch starts and the calculated checksum value equals the stored checksum value, the switch reads
entries from the binding file and adds the bindings to its DHCP snooping binding database. The switch ignores
an entry when one of these situations occurs:
The switch reads the entry and the calculated checksum value does not equal the stored checksum value.
The entry and the ones following it are ignored.
An entry has an expired lease time (the switch might not remove a binding entry when the lease time
expires).
The interface in the entry no longer exists on the system.
The interface is a routed interface or a DHCP snooping-trusted interface.
Catalyst 2960-X Switch Security Configuration Guide, Cisco IOS Release 15.0(2)EX
OL-29048-01 215
Configuring DHCP
DHCP Snooping Binding Database

Table of Contents

Other manuals for Cisco Catalyst 2960-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960-X and is the answer not in the manual?

Cisco Catalyst 2960-X Specifications

General IconGeneral
Console portRJ-45
USB 2.0 ports quantity2
SFP module slots quantity4
Installed SFP modules quantity-
Gigabit Ethernet (copper) ports quantity48
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Power sourceAC
Input current5 A
AC input voltage100 - 240 V
Power consumption (typical)60.9 W
Number of power supply units1
Redundant power supply (RPS) supportYes
Operating altitude0 - 3000 m
Non-operating altitude0 - 4000 m
Storage temperature (T-T)-25 - 70 °C
Operating temperature (T-T)-5 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Switching protocolsUDP, TCP, RADIUS/TACACS+
Number of VLANs1023
Networking standardsIEEE 802.1ab, IEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3af, IEEE 802.3ah, IEEE 802.3at, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Throughput107.1 Mpps
Jumbo frames9216
Number of queues8
MAC address table16000 entries
Number of static routes1000
DHCP featuresDHCP server
AuthenticationMAC-based authentication, Port-based authentication
Security algorithms802.1x RADIUS, SNMP, SSH
Access Control List (ACL) rules3
Switch typeManaged
Switch layerL2/L3
SafetyUL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1
Form factor1U
Product colorBlack
Total Power over Ethernet (PoE) budget370 W
Power over Ethernet (PoE) ports quantity24
Power over Ethernet plus (PoE+) ports quantity12
Memory typeDRAM
Noise level39 dB
Flash memory128 MB
Internal memory512 MB
Processor frequency600 MHz
Mean time between failures (MTBF)276870 h
Weight and Dimensions IconWeight and Dimensions
Depth368 mm
Width445 mm
Height45 mm
Weight5800 g