EasyManuals Logo

Cisco SPA 508G Administration Guide

Cisco SPA 508G
311 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
Configuring Regional Parameters and Supplementary Services
Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones
Cisco Small Business SPA 300 Series, SPA 500 Series, and WIP310 IP Phone Administration Guide 154
7
Advanced Scripting for Cadences, Call Progress Tones, and
Ring Tones
Advanced information on defining tones an and cadences follows.
A CadScript is a mini-script that specifies the cadence parameters of a signal. It
can be up to 127 characters. The syntax follows:
1[;S2]—where Si=Di(oni,1/offi,1[,oni,2/offi,2[,oni,3/offi,3[,oni,4/offi,4[,oni,5/
offi,5[,oni,6/offi,6]]]]]) and is known as a section, oni,j and offi,j are the on/off
duration in seconds of a segment and i = 1 or 2, and j = 1 to 6.
Di is the total duration of the section in seconds. All durations can have up to
3 decimal places to provide 1 ms resolution. The wildcard character “*”
stands for infinite duration. The segments within a section are played in
order and repeated until the total duration is played.
Example 1: Normal Ring
60(2/4)
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60 s
Number of Segments = 1
Segment 1: On=2s, Off=4s
Total Ring Length = 60s
Example 2: Distinctive Ring (short,short,short,long)
60(.2/.2,.2/.2,.2/.2,1/4)
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60s
Number of Segments = 4
Segment 1: On=0.2s, Off=0.2s
Segment 2: On=0.2s, Off=0.2s
Segment 3: On=0.2s, Off=0.2s
Segment 4: On=1.0s, Off=4.0s
Total Ring Length=60s
A ToneScript is a mini-script that specifies the frequency, level and cadence
parameters of a call progress tone. It can contain up to 127 characters. The syntax
follows:
FreqScript;Z1[;Z2]. The section Zi is similar to the Si section in a CadScript
except that each on/off segment is followed by a frequency components
parameter: Zi = Di(oni,1/offi,1/fi,1[,oni,2/offi,2/fi,2 [,oni,3/offi,3/fi,3 [,oni,4/
offi,4/fi,4 [,oni,5/offi,5/fi,5 [,oni,6/offi,6/fi,6]]]]])

Table of Contents

Other manuals for Cisco SPA 508G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SPA 508G and is the answer not in the manual?

Cisco SPA 508G Specifications

General IconGeneral
SpeakerphoneYes
Dialer locationBase
Mac compatibilityNo
Ethernet LAN (RJ-45) ports2
Display resolution128 x 64 pixels
Display number of colorsMonochrome
Headphone connectivity2.5 mm
Weight and Dimensions IconWeight and Dimensions
Depth212 mm
Width214 mm
Height44 mm
Weight900 g

Related product manuals