2-30 Troubleshooting
Table 2-22
Continued
Problem Probable Cause Recommended Action(s)
Phone line noise causes a
disconnection.
Hang-Up Delay S Register
(S10) set too low.
Change S10 default to 150.
1. Click Start
⇒
Programs
⇒
Accessories
⇒
HyperTerminal.
2. Go to Command Mode.
3. Type
ATS10=150
and press
Enter.
This command causes the modem to take
longer to disconnect even if there is noise
on the line.
Ten-digit dialing does not
work correctly under Windows
95.
Ten-digit dialing doesnt work
correctly under Windows 95,
making it difficult to dial
numbers in a different area
code that are not long
distance calls.
Since Windows 95 does not limit the number
of digits you can enter in the Phone Number
field, set the Area Code field to match your
local area code. Then type the ten-digit
telephone number in the Phone Number
field.
Modem cable
disables/interferes with other
telephony devices (Germany,
Austria, and Switzerland only).
The modem cable does not
provide the additional 4-wire
connection required in
Germany, Austria, and
Switzerland to form the serial
pass-through necessary so
that other devices can work
on the same phone line.
To use another telephony device on the
same line in these countries, unplug the
modem cable from the wall jack first.
Modem does not dial correctly
under Windows 95
(Switzerland and Germany
only).
The
“
Wait for dial tone before
dialing
”
check box is checked.
This causes Windows 95 to
issue an ATDT; command. A
typical dial string would look
like this:
ATDT;
ATDTnnn-nnnn
In Germany and Switzerland,
the
‘
;
’
dial modifier is not
permitted to be used in this
fashion by regulatory agencies
since ATDT; takes the modem
off-hook without dialing.
Therefore, the modem returns
an error message when
attempting to dial. The error
message reads:
The computer is not
receiving a response from the
modem. Check that the
modem is plugged in, and if
necessary, turn the modem
off, then turn it back on.
1. Click Start
⇒
Settings
⇒
Control Panel.
2. Double-click the Modems icon.
3. Click the Properties button.
4. Select the Connection tab.
5. Click the
“
Wait for dial tone before
dialing
”
check box to clear it.
6. Click
OK
⇒
Close.