Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–21 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Configuration
(Cont)
fffff=Unit Alarm Mask (MSK)
g=LNB Current Source (LCS)
hh=LNB Current Window (LCW)
i=LNB Current Window Enable (CWE)
j=Enable Statistics Averaging (ESA)
k=Set Statistics Interval (SSI)
l=Enable Statistics Logging (ESL)
m=Auxiliary Mute (AUX)
n=user mute state (MUT)
o=RF power amplifier state (AMP)
COMMAND EXAMPLE: <0001/GAC=a;b;cc.cc;dd.dd;e;fffff;g;hh;I;j;k;l;m;n;o;{CR}
Pointer
Resets internal pointer to allow RNE? queries to start at the beginning of the
stored events log. This command takes no arguments.
IEP?
IEP*
Sets or returns the Current Active Software Image in the form x, where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
COMMAND EXAMPLE: <0001/IMG=1{CR} (instructs the unit to load firmware
from image #1 at the next reset / power up).
QUERY EXAMPLE: <0001/IMG?{CR} (queries the image number that the
firmware loaded during bootup)
NOTE: If you send the IMG command and then query the IMG value, the numbers
may not be equal because the command tells the firmware which image to boot from
at the next bootup, while the query reports the image that the firmware booted from
IMG?
IMG*
IMG#