Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–20 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
Fan Model
Number
FMN=
FMN?
3 bytes
Command or Query.
Sets or returns the fan model number in the form xxx, where:
1=Comair Rotron, 255=ADDA
Default value: 255
Example: <0001/FMN=1{CR} (sets the fan model number to Comair Rotron)
FMN=
FMN?
FMN=xxx
Retrieve
Firmware
Number
N/A
FRW?
Query only.
Returns the Boot, Bulk1, and Bulk2 firmwares loaded into the unit, each firmware
load [a,b,c] is in the form FW-AAAAAAA B.B.BB DD/MM/YY where:
FW-AAAAAAA=the firmware part number
B.B.BB=the version number
DD/MM/YY=Day/Month/Year firmware released
EXAMPLE: <0001/FRW?{CR}
>0001/FRW={CR}
Boot: {CR}
FW-0000082 0.0.1a 04/09/08{CR}
Bulk1: {CR}
FW-0000078 0.0.1a 04/09/08{CR}
FW-0000080 0.0.1a 04/09/08{CR}
FW-0000081 0.0.1a 04/09/08{CR}
Bulk2: {CR}
FW-0000078 0.0.1a 04/09/08{CR}
FW-0000080 0.0.1a 04/09/08{CR}
FW-0000081 0.0.1a 04/09/08{CR}{LF}
FRW=
FRW=Boot
:[a]:{CR}Bu
lk1:{CR}[a]{
CR}[b]{CR}
[c]{CR}Bulk
2:{CR}[a]{C
R}[b]{CR}[c
]{CR}{LF}
Global Amplifier
Configuration
GAC=
GAC?
43 bytes
Command or Query.
Sets or returns the global status of the LPOD, semicolon delimited, in the form
aa.aa;b;ccccc;d;e;f;g;h;j;k;l;m;n;o where:
a=redundancy mode (ESW)
b=online status (ONL)
cc.cc=Attenuation Offset (AOF)
dd.dd=Customer Attenuation(ATT)
e=Auto Fault Recovery (AFR)
GAC=
GAC*
GAC?
GAC#
GAC=x….x