Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–23 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
LNB Current
Source
LCS=
LCS?
1 byte
Command or Query.
Sets or returns the LNB current source in the form x, where:
x=0,1,2,3, or 4:
0=Disable (DEFAULT)
1=Enable (18V 22kHz Disabled SEE NOTE 2)
2=18V 22kHz Enabled (SEE NOTE 2)
3=13V 22kHz Disabled (SEE NOTE 2)
4=13V 22kHz Enabled (SEE NOTE 2)
NOTES:
1) LCS must be enabled before the LNB current can be calibrated
2) This feature is available on multi-band units only.
COMMAND EXAMPLE: <0001/LCS=1{CR}
LCS=
LCS?
LCS*
LCS=x
LNB Current
Window
LCW=
LCW?
2 bytes
Command or Query.
Sets or returns the alarm window in ±% of the calibrated LNB Current in the form xx,
where:
xx=20 to 50, in increments of 1(%); set to 99 to disable (SEE NOTE).
Default value: 30
NOTE: A query return value of 99 indicates that the current window is disabled. This
method is due to become obsolete. Comtech recommends that you use the CWE
command/query instead of specifying 99 here.
COMMAND EXAMPLE: <0001/LCW=30{CR} (sets the alarm window to ±30%)
LCW=
LCW?
LCW*
LCW=xx