Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–25 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
State
Command or Query.
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for
Outdoor SSPA) in the form x, where x=0, 1, 2, or 3::
0=Local
1=Serial
2=Ethernet
3=Serial+Ethernet (DEFAULT)
NOTE: You will always have LRS query access in any mode. The LRS command
is available in all modes as a means of acquiring control so as to limit changes
from being made on multiple interfaces at the same time. Units without a front
panel (e.g., the LPOD) treat an entry of 0 as “reserved” and refuse the command
by returning a mode error. The HTTP Interface prohibits connections unless you
set LRS to accept Ethernet remote control.
COMMAND EXAMPLE: <0001/LRS=3{CR}
LRS?
Address
Returns the read-only MAC address of the unit, in hexadecimal format xx-xx-xx-
xx-xx-xx
EXAMPLE: <0001/MAC?{CR}
>0001/MAC=00-06-B0-00-D2-A7{CR}{LF}
xx-xx-xx-
xx-xx