Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–28 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Unread Stored
Statistics
Unit returns the Number of Unread stored Statistics in the form xxx.
EXAMPLE: <0001/NUS?{CR}
Sets or returns offline mute in the form x, where:
0=Disable (Not Muted)
1=Enable (Muted)
2=Mute RX
3=Mute Tx
4=Mute Rx+LNB
5= Mute Tx+LNB
6=Mute Tx+AMP
7=Mute Tx+LNB+AMP
NOTE: LNB Voltage of Online unit shows on Status page of Offline unit when
Offline Mute is set to 4 or 5. This is caused by voltage feedback from Online unit
to Offline unit via RF splitter.
EXAMPLE: <1/OFM=1{CR}
OFM?