Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–30 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
Retrieve Alarm
Status
(Cont)
A10V1=OK{CR} (+10V1 RF supply) (SEE NOTE)
A10V2=NA{CR} (+10V2 RF supply) (SEE NOTE)
P7V8T=OK{CR} (+7.8V power supply)
P5V8T=OK{CR} (+5.8V power supply)
P2V5T=OK{CR} (+2.5V power supply)
P1V2T=OK{CR} (-1.2V power supply)
N5V8T=OK{CR} (-5.8V power supply)
FANR1=OK{CR} (Fan 1 speed) (SEE NOTE)
FANR2=OK{CR} (Fan 2 speed) (SEE NOTE)
ATEMP=OK{CR} (Amplifier temperature)
SHTDN=OK{CR} (Over-temp shutdown)
IICST=OK{CR} (I2C bus status)
FWPWR=OK{CR} (Forward power in dBm)
CHKSM=OK{CR} (Flash checksum)
FPGAD=NA{CR} (FPGA done status)
BUCLD=OK{CR} (BUC lock detect) (SEE NOTE)
REFLD=NA{CR} (Reference lock detect) (SEE NOTE)
LNBCS=XXXXX{CR} (LNB current status) (SEE NOTE)
SWITC=NA{CR} (Waveguide switch position status) (SEE NOTE)
RDLNK=NA{CR} (Redundancy link status) (SEE NOTE)
TRMST=YS{CR}{LF} (Terminal Status)
NOTE: LNBVT, A10V1, A10V2, FANR1, FANR2, BUCLD, REFLD, LNBCS,
SWITC and RDLNK only appear in the list if the appropriate model/options have
been selected/installed.
Reboot
RBT=
N/A
1 byte
Command only.
Soft Reboots the unit in the form x where:
1=Reboot System
RBT =
RBT?
RBT*
RBT=x