Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–35 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Unread Stored
Events
(Cont)
INFO CODES REPORT AS FOLLOWS:
0=Power Off; 1=Power On; 2=Log Cleared; 3=Global Config Change;
4=Redundancy Config Change
ddmmyy=Date in day/month/year format
hhmmss=Time in hour:minutes:seconds format
NOTES:
1) If less than 5 events are retrieved, the remaining positions are padded with
zeros.
2) If there are no new events, the response is RNE*.
3) A Global Config Change is defined as any time a command is successfully
executed.
4)
A query does not set the status change flag. The status change flag is
cleared after being read. No other events toggle a status change.
Unread Stored
Statistics
Returns the oldest 5 unread stored statistics entries in the reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where:
Sub-body= ddmmyyhhmmssaaa.abbb.bccc.cdd.ddefghhh.hiii.i
ddmmyy=day/month/year
hhmmss=hour:minute:second
aaa.a=Operating Temperature (e.g., +40.0)
bbb.b=Amp Temperature (e.g., +40.0)
ccc.c=RF Power output
dd.dd=Attenuation Setting
e=Amp On/Off
f =Mute On/Off
g=Online/Offline Status
hhh.h=LNB Current (mA)
iii.i=BUC Tuning Voltage
NOTE: If there are less than 5 entries to be retrieved, the remaining positions are
padded with zeros. If there are no new entries, the response is RNS*.
Sub-
body{CR}S
ub-
body{CR}S
ub-
body{CR}S
ub-
body{CR}S
ub-body