LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC) Revision 3
Appendix B MN-LPOD
B–15
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are printable ASCII
characters)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Set RTC (Real-
Time-Clock) Date
E
DAT= 6 bytes Command or Query.
A command in the form mmddyy, where; dd = day of
the month, between 01 and 31, mm = month of the
year, between 01 and 12 and yy = year, between 00
and 96 (2000 to 2096)
Example (date = April 24, 2003):
<1/DAT=240403’cr’
>0001/DAT=’cr’’lf’
DAT=
DAT?
DAT*
DAT?
DAT=xxxxxx
(Same format as
command
arguments)
Set RTC (Real-
Time-Clock) Date
DAY= 6 bytes Command or Query.
A command in the form ddmmyy, where; dd = day of
the month, between 01 and 31, mm = month of the
year, between 01 and 12 and yy = year, between 00
and 99 (2000 to 2099)
Example (date = April 24, 2003):
<1/DAY=250403’cr’
>0001/DAY=’cr’’lf’
DAY=
DAY?
DAY*
DAY?
DAY=xxxxxx
(Same format as
command
arguments)
Enable Statistics
Averaging
ESA= 1 byte Command or Query.
Enables or Disables averaging of statistics data at a
rate of once per second for 10 second. If Disabled,
burst values will be logged instead of averaged values.
0 = Disable
1 = Enable
Example: <1/ESA=0’cr’
>0001/ESA=’cr’’lf’
Default Value: 0
ESA=
ESA?
ESA*
ESA? ESA=x
(Same format as
command
arguments)
Enable Statistics
Logging
ESL= 1 byte Command or Query.
Enables or Disables the statistics logging function.
0 = Disable
1 = Enable
Example: <1/ESL=1’cr’
>0001/ESL=’cr’’lf’
Default Value: 0
ESL=
ESL?
ESL*
ESL? ESL=x
(Same format as
command
arguments)