LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC) Revision 3
Appendix B MN-LPOD
B–16
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are printable ASCII
characters)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Enable
Redundancy
Switch Mode
ESW= 1 byte Command or Query.
Turns ON or OFF the redundancy state, where:
0 = Off
1 = 1:1 Redundancy TX (Only TX switch installed)
2 = 1:1 Redundancy TX + RX (TX and RX switch
installed)
5 = 1:1 Manual redundancy mode (used for debugging,
or redundant system setup). Manual redundancy does
not support automatic switching, and the offline unit
will not poll the online unit to update its configuration.
Example: <1/ESW=1’cr’
>0001/ESW=’cr’’lf’
Default Value: 0
ESW=
ESW?
ESW *
ESW? ESW=x
Retrieve
Firmware Number
N/A Query only
Returns the firmware type(s) loaded into the unit. The
firmware information is returned in the following format:
FW-AAAAAAA B.B.BB DD/MM/YY
Where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
Example:
<1/FRW?’cr’
>0001/FRW=
Boot:
FW-0000082 0.0.1a 04/09/08
Bulk1:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
Bulk2:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
FRW= FRW? FRW={CR}Boot:{
CR}abc{CR}Bulki:
{CR}abc{CR}abc
(See Description
of Arguments for
details)