47Maintenance
7.5 Notes on cleaning the unit components
Unit component What to clean and how to clean
Steam tank / steam tank strainer
Carefully brush off any limescale from the components
(do not use a wire brush).
If the components are heavily calcied, place them in
an 8% formic acid solution (observe safety notes in
chapter 7.6), until the limescale comes off.
Wash components with a lukewarm soap solution, then
rinse well with tap water.
Steam tank cover and
Heatingelements
Immerse cover with heating elements tted to 2 cm
below the rim of the cover in a container with 8% formic
acid (observe safety notes in chapter 7.6). Allow the
acid to take effect until the scale coating on the heating
elements has dissolved.
Note: The heating elements do not have to be entirely
free from scale.
Rinse heating elements thoroughly with fresh water.
CAUTION! Ensure that the electrical connections re-
main dry.
CAUTION! On no account remove scale coating on the
heating elements with tools (screwdriver, scraper, etc.)
or by striking. This could damage the heating elements.
Carefully remove any limescale underneath the cover
and on the thermostat(s) with a soft bristled brush (do
not use a wire brush). The thermostat must be free of
limescale.
Hoses
Remove any limescale in the hoses by carefully twisting
and the hoses. Then, rinse the tubes well with hot tap
water.