49Maintenance
Unit component What to clean and how to clean
Level unit
Float
(Magnet must be
on the bottom)
Disassemble level unit.
Carefully remove any limescale inside the housing of
the level unit and its connectors using a soft bristled
brush (do not use a wire brush).
If the housing of the level unit is heavily calcied, place
it in an 8% formic acid solution (observe safety notes
in chapter 7.6), until the limescale comes off.
CAUTION! Remove any limescale on the oat using a
soft bristled brush (do not use a wire brush)!
Carefully remove any limescale on the oat using a soft
bristled brush (do not use a wire brush)!
Wash components of the level unit with a lukewarm
soap solution and rinse well with tap water.
Reassemble level unit.
Important:Wheninsertingtheoatinthehousing
of the level unit make sure that the magnet of the
oatpointstothebottomofthehousing.
Interior of the unit
(water side only)
Wipe the interior of the unit with a damp cloth without using
any cleaning agent.
CAUTION: Take care that the electrical connections and
the electronic components remain dry!
7.6 Notes on cleaning agents
Only use cleaning agents stated in the table above. The use of disinfectants is only permitted if they
do not leave any toxic residues. In any case the parts must be thoroughly rinsed with clean drinking
water after cleaning.
WARNING!
Formic acid is harmful to the skin, eyes and the respiratory tracts. Therefore prevent your skin, eyes
and respiratory tracts from getting in touch with the acid and its vapours (wear gloves, goggles and
work in a well ventilated room or outside).
CAUTION!
Donotuseanysolvents,aromatizedorhalogenizedhydrocarbonsorotheraggressivesub-
stances as they may cause damage to the components of the unit.
It is mandatory to observe and comply with the manufacturers information and instructions regarding
the cleaning agents used. Observe in particular: all information relating to the protection of personnel,
environmental protection and restrictions regarding usage.