FSG/MTM/001 060511
157
Remove the two fixing screws, one on the left and one on the right side plate.
Do not grip on the Mirror Chassis when lifting the scanner for removal of the Bottom Plate.
8.5 Top Profile (Lid)
On scanners with ATAC:
Remove the Streamer and the four fixing screws located behind the Streamer.
Open the Top Cover (Lid)
On all scanner models:
Release the lock screw in one of the bearings of the Top Profile.
Slide the bearing off and lift off the Top Profile
8.6 Original Guide Plate with ATAC
Move Original Guide Plate to upper position.
Open Original Guide Plate.
Remove Streamer and the four fixing scews located behind the Streamer.
Open the Top Cover.
Disconnect cable from MDAB-Board.
Pull the cable off the Original Guide Plate.
Remove the two fixing screws for the hinge bushings.
Lift off the Original Guide Plate.
8.7 Glass Plate
On 25”, 36” and 40” scanners:
The Glass Plate is hinged on two small brass bearings, one on each side plate.
Remove the mounting screws for the two bearings and lift off the Glass Plate.
When replacing the Glass Plate, the bearing should be mounted with the flange against the
side plate.
On scanners with ATAC:
Move Original Guide Plate to upper position.
Open Original Guide Plate.
Open the Glass Plate and lift it off its hinges.
8.8 Entry Roller Shield
Remove the Top Cover.
Remove the Original Guide Plate.