FSG/MTM/001 060511
177
10.1.13 Test 21, SCANdump
Purpose: To create a file, SCANdump.con, which contains Light Profiles and other scanner
data for diagnostics purposes.
Description: The file SCANdump.con will be placed in the directory pointed to by the SET
TEMP environment variable.
The files contained in SCANdump.con may be unpacked by SCANview 6 by double clicking
on SCANdump.con.
The unpacked Light Profiles may be viewed by SCANview 6. If other files are included use
an appropriate reader or viewer.
10.1.14 Test 27, Camera Adjustment Wizard
See also Test 9, Camera Adjustment
Purpose: To support CCD-Camera adjustments.
Description: The Camera Wizard provides a guide for a complete adjustment of all cameras
of the actual scanner, just start Test 27 and follow the instructions given by the Wizard.
10.1.15 Test 28, Original Guide Sensor Test
Purpose: To support check and adjustment of the sensors located in the Original Guide with
ATAC.
Description: see Section 3.15, page 69.
10.1.16 Test 30, Calibrate ATAC
This test applies only to scanners with ATAC and has been implemented from firmware
release 50 (Build 799) and SCANtest 6 version 7.0.1.
Purpose: To set the current level at which the ATAC will stop if something is preventing the
guide plate from moving.
The first scanners shipped had a predefined current level but with this new test the ATAC
system adapts to the actual friction level of the system.
To calibrate the ATAC simply run Test 30. If the calibration fail this is most likely because
the tacho sensor is not functioning. In this case please refer to FSG/TSB/003 which describes
how to correct this problem.