EasyManua.ls Logo

Contex COUGAR 36 - Original Guide Sensors (ATAC)

Contex COUGAR 36
258 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FSG/MTM/001 060511
162
Lift out the Feed Roller Shaft.
When removing the shaft, note the number and position of washers on the ends of the shaft
for later replacement.
After replacement, readjust the Original Sensors, see Section 3.14, page 66 and check Media
Thickness Detector, see Section 3.17, page 78.
9.2 Original Sensor Actuators
Remove the Feed Roller Shaft.
Remove the Torsion Spring from the actuator.
Remove the Thickness Detector at the Operator Panel end.
Loosen (do not remove) the screws holding the bearings of the actuator just enough to allow
the Original Sensor Actuator to be lifted out of the bearing.
Remove the Original Sensor Actuator.
After replacement, readjust the Original Sensors, see Section 3.14, page 66 and check Media
Thickness Detectors, see Section 3.17, page 78.
9.3 Stitching Wire
Remove the Reflector Assembly.
Remove the fixing screws, clamps, and leaf springs for the Stitching Wire and remove the
defective wire.
When replacing the Stitching Wire, make sure that it is placed in the notches of the leaf
springs.
The Stitching Wire should be tightened to give a deflection of 2 – 2.5 mm on each of the two
leaf springs, see
Fig. 5-2, page 132.
9.4 Fluorescent Lamp
CAUTION:
Turn the power switch OFF and disconnect the power plug.
Remove the Top Cover.
Remove the Original Guide Plate.
Remove the End Cover at the Power Inlet end.
Remove the fixing screw under the Lamp Holder.
Pull off the Lamp Holder.
The Fluorescent Lamp may now be pulled out.