FSG/MTM/001 060511
158
Remove the two front most guide pins for the Original Guide Plate (25”, 36” and 40”
scanners).
Remove the Glass Plate (be careful not to loose the two bearings when lifting off the Glass
Plate in 25”, 36” and 40” scanners).
Loosen (do not remove) the twelve (25” scanners) or sixteen (36“ and 40” scanners) or 24
(54” scanner) screws (half are Allen screws and half are screws with 6 mm hexagonal head)
on the front side of the Entry Roller Shield.
Caution: 36”, 40”, and 50” scanners only: Do not loosen the two fixing screws for the center
bearing of the Feed Roller (5.5 mm hexagonal heads or Allen screws secured by seal
lacquer).
Gently remove the Entry Roller Shield (be careful not to bend or in any other way damage the
shield).
When replacing the Entry Roller Shield, the Glass Plate must be mounted and closed down
before tightening the fixing screws of the Entry Roller Shield. While tightening the screws,
gently press the Entry Roller Shield downwards so that the rear edge of the Entry Roller
Shield is in contact with the edge of the Glass Plate. This is to prevent the original from being
caught by the edge of the Entry Roller Shields when it is moving backwards.
8.9 Exit Roller Shield
For 25”, 36” and 40” scanners
Remove the Top Profile (Lid).
Remove the Original Guide Plate.
Remove the two rear guide pins for the Original Guide Plate.
Remove the left and right hinges for the Top Profile (Lid).
For 54” scanner
Remove Original Guide Plate.
Remove the Rear Cover.
Loosen (do not remove) the twelve (25” scanners) or sixteen (36“ and 40” scanners) or 24
(54” scanner) screws (half are Allen screws and half are screws with 6 mm hexagonal head)
on the front side of the Entry Roller Shield.
Caution: 36”, 40”, and 54” scanners only: Do not loosen the two fixing screws for the center
bearing of the Feed Roller (5.5 mm hexagonal heads or Allen screws secured by seal
lacquer).
Gently remove the Entry Roller Shield (be careful not to bend or in any other way damage the
shield).