FSG/MTM/001 060511
166
Run Scanner Maintenance.
9.12 Slider for Media Thickness Adjustment
Does not apply to scanners with ATAC
Remove the Original Guide Plate from the scanner.
Place the Original Guide Plate with the front down.
Remove the two fixing screws and guide bushings for the Adjustment Slider.
The Adjustment Slider may now be removed.
9.13 Elevation Motor (ATAC)
Open Top Cover (Lid) of Original Guide Plate.
Remove the two (M3) fixing screws for the motor bracket.
Pull the motor with bracket off.
Move motor bracket and the flexible coupling to the new motor.
Re-install the motor and adjust the flexible coupling to a play of 1 mm, see Fig. Fig. 3-26,
page 74.
Secure the motor cable with cable ties.
9.14 Original Guide Sensors (ATAC)
See Fig. 3-24, page 72 and Fig. 3-25, page 73
Open Top Cover (Lid) of Original Guide Plate.
Remove the fixing screws for the sensor bracket.
Click the sensor off the bracket and replace.
Install the sensor and adjust as described in Section 3.15, page 69