FSG/MTM/001 060511
55
SW
1
SW
2
SW
3
SW
4
SW
5
SW
6
SW
7
SW
8
HE
X
COUGAR Tx 36
OFF OFF
ON
OFF OFF OFF
ON ON
0x23
CHAMELEON Tx 36
OFF OFF
ON
OFF OFF
ON ON
OFF 0x26
PREMIER Tx 36
OFF OFF
ON
OFF OFF
ON ON ON
0x27
An undefined switch setting may cause the ‘Invalid Scanner ID’ Error Code to be displayed
on the Operator Panel, see Section 7.4, page 152.
CAUTION:
The Scanner ID Switch setting is stored in the Flash Memory on the SUC-Board. Every time
the scanner is switched ON, it reads the switch setting and if it is different from the stored
value, the new setting will be stored and all other stored scanner parameters (including
Stitching, Basic Calibration and Color Calibration) will be cleared to default values.
This means that the scanner must be calibrated using Scanner Maintenance afterwards to
restore the actual values.