This parameter controls access via the drive LED keypad as follows:
The LED keypad can adjust this parameter even when user security is set.
When this bit is set to one the motor 2 parameters in menu 21 become active instead of the equivalent parameters in other menus. Changes will only
be implemented when the drive is disabled. When the motor 2 parameters are active the decimal point that is second from the right on the 1st row of
the display is lit. If this parameter is one when an autotune is carried out (Pr 5.12 = 1), the results of the autotune are written to the equivalent second
motor parameters instead of the normal parameters. Each time this parameter is changed the accumulator for motor thermal protection is reset to
zero.
Displays the last loaded defaults.
This parameter is used to start and stop the drive Onboard Application Lite program.
The Drive Onboard Application Lite Ladder Program Status parameter indicates to the user the actual state of the drive Onboard Application Lite
Ladder Program. (not installed / running / stopped / tripped.)
Value String Action
0 L1 Only menu 0 can be accessed
1 L2 All menus can be accessed
2 Loc
Lock user security when drive is reset.
(This parameter is set to L1 after reset)
11.45 Motor 2 parameters select
Coding
BitSPFIDETEVMDPNDRANCNVPTUSRWBUPS
111
Default 0
Update rate Background read
11.46 Defaults previously loaded
Coding
BitSPFIDETEVMDPNDRANCNVPTUSRWBUPS
1111
Range 0 to 2
Default 0
Update rate Background write
11.47 Drive Onboard Application Lite Ladder Program Enable
Coding
BitSPFIDETEVMDPNDRANCNVPTUSRWBUPS
111
Range 0 to 2
Default 2
Update rate Background read
Value Description
0 Halt the Drive Onboard Application Lite ladder Program.
1
Run the Drive Onboard Application Lite ladder Program (if installed). Any out-of-range
parameter writes attempted will be clipped to the maximum / minimum values valid for that
parameter before being written.
2
Run the drive Onboard Application Lite ladder Program (if installed). Any out-of-range
parameter writes attempted will cause a drive trip.
11.48 Drive Onboard PLC program status
Coding
BitSPFIDETEVMDPNDRANCNVPTUSRWBUPS
111
Range -128 to +127
Update rate Background write