Next instructions describe its use in the different phases of the test.
1) Beginning of the test (rapid approach):
Lever A up and Lever B back: Maximum piston
speed upwards;
2) Load control phase:
Lever A up and lever B slowly forward: Piston
speed upwards controlled by load rate control
valve;
3) Load rate adjustment:
Turn the knob until getting proper load rate (read
load rate indicator on the WIZARD 2 display);
4) End of the test:
Lever B slowly back and lever A down to
discharge the oil pressure.