318832000
2. Adjust syrup tanks system or bag-in-box syrup system syrup pumps secondary CO
2
regulator as instructed
in SERVICE AND MAINTENANCE section of this manual.
3. Sanitize all syrup systems as instructed in SERVICE AND MAINTENANCE section of this manual.
4. Install syrup tanks or bag-in-boxes containing syrup into syrup systems
UNIT OPERATION
BLEEDING SYRUP AND APPLICABLE PLAIN OR CARBONATED WATER SYSTEMS
1. Make sure Unit keyed lock-out switch is in “ON” (vertical) position.
2. Dispense from each dispensing valve until air is bled from systems and until syrup and applicable plain or
carbonated water are dispensed.
3. Check for syrup and water leaks and tighten any loose connections.
4. Install Unit hood and secure with screw.
ADJUST WATER-TO-SYRUP “RATIO” OF DISPENSED PRODUCT
1. On dispensing valves equipped with adjustable water flow regulators, adjust for water flow rate as
instructed in SERVICE AND MAINTENANCE section of this manual.
2. Adjust dispensing valves for Water-to-Syrup “Ratio” of dispensed drinks as instructed in SERVICE AND
MAINTENANCE section of this manual.
3. Install Unit front access panel.
INSTALL DECALS
Install DECALS (provided with Unit) on dispensing valve covers.