NON-CARBONATED UNIT (CONTD)
Trouble Probable Cause Remedy
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE.
A. Recovery rate of refrigeration
unit exceeded, ice bank
depleted.
A. Allow ice bank to recover.
CAUTION: The drop-in refrigeration assembly condenser coil must be
periodically cleaned. Excessive accumulation of dust, lint, and grease
on coil will restrict cooling air flow through coil and cause
refrigeration system to overheat.
B. Dispensing valve restricted or
dirty.
B. Sanitize syrup system as
instructed.
C. Tapered gasket inside
carbonated water line swivel
nut connector distorted
restricting carbonated water
flow.
C. Replace tapered gasket. Make
sure gasket is properly seated.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES.
A. Dispensing valves keyed
lock-out switch in OFF
position.
A. Place keyed lock-out switch in
ON position.
B. No electrical power to Unit. B. Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker.
C. Disconnected dispensing
valves power cord.
C. Connect dispensing valves power
cord.
D. Disconnected or broken wiring
to dispensing valve.
D. Connect or replace wiring.
E. Inoperative transformer or
valve solenoids.
E. Replace inoperative part.
ONLY PLAIN WATER
DISPENSED.
A. Out of syrup. A. Replenish syrup supply as
instructed.
B. Inoperable dispensing valve. B. Repair dispensing valve.
C. Dispensing valve syrup flow
control not properly adjusted.
C. Adjust dispensing valve syrup
flow control (Water-to-Syrup
Ratio) as instructed.
D. Dispensing valve syrup flow
control or syrup lines
restricted.
D. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Water inlet supply line shutoff
valve closed.
A. Open water inlet supply line
shutoff valve.
REFRIGERATION SYSTEM
Trouble Probable Cause Remedy
COMPRESSOR DOES NOT
OPERATE.
A. Ice bank sufficient. A. Refrigeration not called for.
B. Unit power cord unplugged,
power switch (if applicable) in
OFF position, or drop-in
refrigeration assembly power
cord unplugged.
B. Plug in power cord(s) or place
Unit power switch (located behind
front panel) in ON position.