UNIT WITH BUILT-IN COLD CARBONATOR
Trouble Probable Cause Remedy
WATER-TO-SYRUP RATIO
TOO LOW OR TOO HIGH
A. Dispensing valve syrup flow
control not properly adjusted.
A. Adjust Water-to-Syrup Ratio as
instructed.
B. Syrup Tanks System.
CO
2
gas pressure to syrup
tanks insufficient to push syrup
out of tanks.
Bag-in-Box Syrup System.
CO
2
gas pressure to syrup
pumps insufficient to operate
pumps.
B. Adjust CO
2
regulator for syrup
tanks as instructed.
Adjust syrup pumps CO
2
regulator as instructed.
ADJUSTMENT OF
DISPENSING VALVE SYRUP
FLOW CONTROL DOES NOT
INCREASE TO DESIRED
WATER-TO-SYRUP RATIO.
A. No syrup supply. A. Replenish syrup supply as
instructed.
B. Syrup Tanks System.
Syrup tanks CO
2
regulator out
of adjustment.
Syrup Bag-in-Box System.
Syrup pumps CO
2
regulator
out of adjustment.
B. Adjust syrup tanks CO
2
regulator
as instructed.
Adjust syrup pumps CO
2
regulator as instructed.
C. Dispensing valve syrup flow
control, or syrup line restricted.
C. Sanitize syrup system as
instructed.
D. Improper syrup Baume. D. Replace syrup supply as
instructed.
E. Inoperative dispensing valve
syrup flow control.
E. Repair dispensing valve syrup
flow control.
F. Tapered gasket inside tube
swivel nut connection distorted
from being overtightened
restricting syrup flow.
F. Replace tapered gasket. Make
sure it is properly seated.
ADJUSTMENT OF
DISPENSING VALVE SYRUP
FLOW CONTROL DOES NOT
DECREASE TO DESIRED
WATER-TO-SYRUP RATIO.
A. Dirty dispensing valve syrup
flow control.
A. Disassemble and clean
dispensing valve syrup flow
control.
DISPENSED PRODUCT
CARBONATION TOO LOW.
A. Carbonator CO
2
regulator out
of adjustment for existing
water conditions or
temperature.
A. Adjust carbonator CO
2
regulator
as instructed.
B. Air in carbonator tank. B. Vent air from carbonator tank by
dispensing from dispensing valve
to make carbonator pump motor
cycle on.
C. Water, oil, or dirt in CO
2
supply.
C. Remove contaminated CO
2
.
Clean CO
2
system (lines,
regulators, etc.) using mild
detergent. Install clean CO
2
supply.