45
318832000
STANDARD UNIT (REMOTE REQUIRES CONNECTION TO A REMOTE CARBONATOR)
CONT’D
Trouble Probable Cause Remedy
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE.
(cont’d)
E. Tapered gasket inside
carbonated water line swivel
nut connector distorted
restricting carbonated water
flow.
E. Replace tapered gasket. Make
sure it is properly seated.
F. Dirty water supply. F. Check water filter. Replace
cartridge (see NOTE).
NOTE: If water supply is dirty, be sure to flush lines and carbonator
completely. It may be necessary to remove lines to carbonator tank,
invert tank, and flush tank and all inlet lines to remove any foreign
particles or dirt.
NO PRODUCT DISPENSED. A. Dispensing valves keyed
lock-out switch in “OFF”
position.
A. Place keyed lock-out switch in
“ON” position.
B. No electrical power to Unit. B. Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker.
C. Disconnected dispensing
valves power cord.
C. Connect dispensing valves power
cord.
D. Disconnected or broken wiring
to dispensing valve.
D. Connect or replace wiring.
E. Inoperative transformer or
valve solenoids.
E. Replace inoperative part.
ONLY CARBONATED WATER
DISPENSED.
A. Out of syrup. A. Replenish syrup supply as
instructed.
B. Inoperable dispensing valve. B. Repair dispensing valve.
C. Dispensing valve syrup flow
control not properly adjusted.
C. Adjust dispensing valve syrup
flow control (Water-to-Syrup
“Ratio”) as instructed.
D. Dispensing valve syrup flow
control or syrup lines
restricted.
D. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Water inlet supply line shutoff
valve closed.
A. Open water inlet supply line
shutoff valve.
B. Carbonator power cord
unplugged from electrical
outlet.
B. Plug carbonator power cord into
electrical outlet.
C. Carbonator CO
2
regulator not
properly adjusted.
C. Adjust carbonator CO
2
regulator
as instructed.